Ulf Forsberg
Contact
E-mail
ulf.forsberg@umu.se
Works as
Affiliation
Research fellow
at
Department of Public Health and Clinical Medicine
Location
1, Skellefteå lasarett
Umeå universitet, 901 85 Umeå
Publications
Publications
2024
The Emboless® venous chamber efficiently reduces air bubbles: a randomized study of chronichemodialysis patients
Clinical Kidney Journal
, Oxford University Press 2024, Vol. 17, (11)
Forsberg, Ulf; Jonsson, Per; Stegmayr, Bernd
2023
Microemboli induced by air bubbles may be deposited in organs as a consequence of contamination during medical care
Clinical Kidney Journal
, Oxford University Press 2023, Vol. 16, (1) : 159-166
Forsberg, Ulf; Jonsson, Per; Stegmayr, Bernd
2023
Venous chambers in clinical use for hemodialysis have limited capacity to eliminate microbubbles from entering the return bloodline: an in vitro study
Artificial Organs
, John Wiley & Sons 2023, Vol. 47, (6) : 961-970
Jonsson, Per; Stegmayr, Christofer; Stegmayr, Bernd; et al.
2021
Interdialytic weight gain of less than 2.5% seems to limit cardiac damage during hemodialysis
International Journal of Artificial Organs
, SAGE Open 2021, Vol. 44, (8) : 539-550
Goto, Junko; Forsberg, Ulf; Jonsson, Per; et al.
2019
Air contamination during medical treatment results in deposits of microemboli in the lungs: an autopsy study
International Journal of Artificial Organs
, Sage Publications 2019, Vol. 42, (9) : 477-481
Forsberg, Ulf; Jonsson, Per; Stegmayr, Bernd
2014
EVALUATION OF AIR MICRO BUBBLES IN DIALYSIS SYSTEMS IN VITRO
American Journal of Kidney Diseases
, Vol. 63, (5) : A61-A61
Jonsson, Per; Forsberg, Ulf; Stegmayr, Bernd
2013
Presence of microemboli during haemodialysis and methods to reduce the exposure to microbubbles
Umeå University medical dissertations
, 1564
Ulf, Forsberg
2013
A high blood level in the venous chamber and a wet-stored dialyzer help to reduce exposure for microemboli during hemodialysis
Hemodialysis International
, Vol. 17, (4) : 612-617
Ulf, Forsberg; Jonsson, Per; Stegmayr, Christofer; et al.
2012
A high blood level in the air trap reduces microemboli during hemodialysis
Artificial Organs
, Vol. 36, (6) : 525-529
Forsberg, Ulf; Jonsson, Per; Stegmayr, Christofer; et al.
2012
Microbubbles of air may occur in the organs of hemodialysis patients
ASAIO journal (1992)
, Vol. 58, (2) : 177-179
Stegmayr, Bernd; Brännström, Thomas; Forsberg, Ulf; et al.
2011
Micro embolies of air are deposited in the organs in hemodialysis patients: a case report
International Journal of Artificial Organs
, Vol. 34, (8) : 636-636
Brännström, Thomas; Forsberg, Ulf; Jonsson, Per; et al.
2010
Microemboli, developed during haemodialysis, pass the lung barrier and may cause ischaemic lesions in organs such as the brain
Nephrology, Dialysis and Transplantation
, Vol. 25, (8) : 2691-2695
Forsberg, Ulf; Jonsson, Per; Stegmayr, Christofer; et al.
2008
Hemodialysis dialyzers contribute to contamination of air microemboli that bypass the alarm system in the air trap.
International Journal of Artificial Organs
, Vol. 31, (4) : 317-22
Stegmayr, Christoffer; Jonsson, Per; Forsberg, Ulf; et al.
2007
Response to letter to the editor.
Artif Organs
, Vol. 31, (12) : 913-4
Jonsson, Per; Forsberg, Ulf; Stegmayr, Christofer; et al.
2007
Air bubbles pass the security system of the dialysis device without alarming.
Artificial Organs
, Vol. 31, (2) : 132-139
Jonsson, Per; Karlsson, Lars; Forsberg, Ulf; et al.
2007
The sensor in the venous chamber does not prevent passage of air bubbles during hemodialysis
Artificial Organs
, Vol. 31, (2) : 162-166
Stegmayr, Bernd; Forsberg, Ulf; Jonsson, Per; et al.
2007
Development of air micro bubbles in the venous outlet line: an in vitro analysis of various air traps used for hemodialysis.
Artif Organs
, Vol. 31, (6) : 483-8
Stegmayr, Christofer J; Jonsson, Per; Forsberg, Ulf; et al.
2001
Electrical current leakage during hemodialysis may increase blood-membrane interaction
International Journal of Artificial Organs
, Wichtig Editore Srl 2001, Vol. 24, (3) : 136-139
Jonsson, Per; Forsberg, Ulf; Niklasson, Johan; et al.
View publications in DiVA
+ Show more
- Show less